Sitol A

Solvent-based bituminous protective paint.

Solvent-based bituminous protective paint.

  • Prevents dusting and porosity in concrete
  • Rapid film drying, no stickiness
  • Facilitates the application of bitumen-polymer membranes, ensuring effective bonding
  • Excellent adhesion and penetration on all dry cementitious surfaces
  • Does not run at high temperatures and does not become brittle at low temperatures
  • No residual oily substances on the surface
  • Mild, non-persistent odour

Application areas

Choose Sitol A for

  • Primer for concrete structures such as viaducts, bridges, foundation walls, and the roofs of civil and industrial buildings.
  • It must be applied before bonding hot- or cold-applied polymer-modified bituminous membranes, or before coating with liquid bituminous membranes.
  • Used as a waterproofing paint on concrete foundation walls, and as a consolidating primer for concrete, timber and metal surfaces.
  • It is used in the preparation of metal and timber surfaces.

Discover more

Other solutions you might be interested in

Details

Sitol A is a ready-to-use black paint, based on special bitumens with high resistance to ageing, dissolved in solvents. It can be applied by brush or spray. It dries quickly, forming an elastic, durable, non-sticky film with a high softening point and excellent adhesion. It effectively protects cementitious and metallic substrates from atmospheric agents, water, industrial gases, saline solutions and humic acids from the subsoil, which attack and corrode buried elements. Sitol A is not resistant to the action of solvents, oils and fuels.

Instructions for use

Ensure that any loose, flaking or poorly adhering parts, paint, rust, dust and release agents are removed, and thoroughly clean the surfaces, which must be sound and dry. Avoid application if weather conditions are expected to adversely affect the product’s proper drying. Apply at temperatures between 0°C and +35°C; avoid extreme heat and cold during application and whilst the film is drying. Application can be carried out using a brush, wide-bristle brush, roller or spray. Equipment can be cleaned using standard synthetic or nitro thinners.

Storage

If stored in a cool, dry place in its original, unopened packaging, the product will keep for at least 24 months.

Warnings

When applying hot-applied polymer-modified bitumen membranes using a flame, the use of a primer is recommended only if the concrete surfaces are perfectly dry; otherwise, it is advisable to use a bituminous primer specifically designed for damp surfaces. Before laying the membrane, check that the product is completely dry. Ensure that any cracks and ventilation systems are sealed before application. Do not use inside residential buildings or in unventilated areas. Do not use to waterproof surfaces or containers intended to hold food-grade liquids, drinking water, or those that come into contact with solvents or mineral oils. Do not expose the material to direct sunlight or temperatures exceeding 30 °C. Flammable product. Do not expose to temperatures exceeding 30 °C, direct sunlight, heat sources, open flames or other sources of ignition. Follow the information provided on the safety data sheet.

Color Code Packaging Packaging size Pallet Barcode
Black
8176 metal bucket 18x1 l
24 cardboards
Barcode 8030334081767
Black
8177 metal bucket 5 l
96 metal buckets
Barcode 8030334081774
Black
8178 metal bucket 20 l
33 metal buckets
Barcode 8030334081781

  • Primer for concrete structures such as viaducts, bridges, foundation walls, and the roofs of civil and industrial buildings.
  • It must be applied before bonding hot- or cold-applied polymer-modified bituminous membranes, or before coating with liquid bituminous membranes.
  • Used as a waterproofing paint on concrete foundation walls, and as a consolidating primer for concrete, timber and metal surfaces.
  • It is used in the preparation of metal and timber surfaces.

PARAMETER AND TEST METHOD VALUES
Colour black
Consistency liquid
Closed-cup flash point ASTM D3828-87 > +23 °C
Dry residue (m/m at 130 °C) UNI EN ISO 3251 (59–65)% (59–65)%
Viscosity (Flow time at 20 °C, DIN cup/4 mm) UNI EN ISO 2431 25–35 seconds
Density (at 20 °C) UNI EN ISO 2811-1 (0.97 ± 0.03) kg/L
Dust-free drying time 15–25 minutes*
PERFORMANCE CHARACTERISTICS (EN 1504-2:2004 – C COATINGS – PI MC IR
CO₂ permeability UNI EN 1062-6 SD > 50 m
Water vapour permeability UNI EN ISO 7783 Class I (SD < 5 m)
Free water permeability UNI EN 1062-3 w < 0.1 kg/m²·h⁰.⁵
Direct tensile adhesion UNI EN 1542 ≥ 1 N/mm²

* Values recorded at a temperature of 23°C and 50% relative humidity. The figures given may vary depending on the thickness of the applied product and the specific site conditions: temperature, humidity, ventilation and absorbency of the substrate.

The approximate primer consumption ranges from 100 to 200 g/m², and depends on the porosity of the substrate to which it is applied.

Technical datasheet
Safety data sheet

Still missing information?