Evaproof Band
Flexible, waterproof polyolefin elastic tape, for sealing joints and upstands in the Evaproof system.
Flexible, waterproof polyolefin elastic tape, for sealing joints and upstands in the Evaproof system.
Discover more
Evaproof Band is a flexible, waterproof, elastic polyolefin tape produced by extrusion. It is used in conjunction with Evaproof Adhesive, a polyurethane adhesive, to ensure the continuity of the waterproofing in the Evaproof system and for treating vertical upstands. The tape is made from polyolefin based on EVAC (ethylene vinyl acetate copolymer): its elasticity allows it to compensate for and absorb dimensional variations in the substrates. Both sides are coated with polyester fibre fabrics, which ensure excellent adhesion to substrates when used with cementitious adhesives classified as C2 S1/S2 in accordance with standards UNI EN 12004 and UNI EN 12002.
Preparation for installation on screeds
Before installing Evaproof Band, carefully assess the condition of the substrate, which must be free from cracks and must meet the requirements of the UNI 11493 standard in terms of curing, integrity, mechanical and surface strength, dimensional regularity, moisture content and the absence of contaminants. Any other substrate must be compact, solid, dry, clean and free from loose particles. Any imperfections in the surface must be levelled out beforehand using specific cementitious mortars. Residues of primer, oils, greases, efflorescence, old coatings, paint or flaking layers must be removed before the tape is laid. Flaking, porous or highly absorbent surfaces must be treated with suitable consolidating products.
Installation instructions for Evaproof membrane
Sealing the joints: at least 12–24 hours after treating the installation surface with Evaproof Primer. Using a 3 mm notched trowel, apply the single-component polyurethane Evaproof Adhesive along the joints and bond the Evaproof Band (13 cm wide) to the adhesive whilst it is still fresh. Using a plastic trowel, apply even pressure (from the centre towards the edges) along the entire length of the tape to eliminate any air bubbles and remove excess product. At the joints, overlap the strips by at least 5 cm, rounding off the corners of the overlaps to improve adhesion. Accessories: to waterproof the corners correctly, use the special Evaproof Corner 90° and Evaproof Corner 270° accessories. Position them using the single-component polyurethane Evaproof Adhesive and apply sufficient pressure with a plastic trowel to remove any excess product and air bubbles. All overlaps between the various elements (corner tape, edge tape and tape-to-tape) must be at least 5 cm and must always be secured using Evaproof Adhesive.
Vertical upstands: first bond a strip of Evaproof membrane, 15–20 cm high, to the vertical upstands using C2 S1/S2 cementitious adhesive. Waterproof the horizontal surface with Evaproof membrane in accordance with the installation and sealing instructions set out in the relevant technical data sheet. For the upstands, use 13 cm wide Evaproof Band: using Evaproof Adhesive, bond the tape partly to the vertical surface, flush against the strip of Evaproof previously laid, and partly overlapping the membrane laid on the floor. To ensure a perfect seal, use a plastic trowel to apply firm pressure along the entire length of the tape, removing any excess product and air bubbles.
Store Evaproof Band in its original packaging, in a well-ventilated, dry place, at a maximum temperature of 30 °C, avoiding direct exposure of the material to sunlight.
Do not apply Evaproof Band:
Evaproof Band must be installed at temperatures between +5 °C and +35 °C.
| Code | Packaging | Packaging size | Barcode |
|---|---|---|---|
| 15648 | roll | 13 cm x 30 m |
Evaproof Band is used with the Evaproof waterproofing system to:
Special Evaproof Corner 90° (internal corner) and Evaproof Corner 270° (external corner) elements are available for joining and waterproofing internal and external corners with vertical and horizontal surfaces.
| Characteristic (Standard) | Tolerance | Value |
| Characteristics | ||
| Length (EN 1848-2) | MDV: -0 % and +5 % | 30 m |
| Width (EN 1848-2) | MDV: -0.5% to +1% | 12.7, 30 and 50 cm |
| Weight (EN 1849-2) | MDV: -5 per cent and +10 per cent | 335 g/m² |
| Thickness (EN 1849-2) | MDV: -5 % and +10 % | 0.52 mm |
| Straightness (EN 1848-2) | MLV g ≤ 50 | 50 mm |
| Flatness (EN 1848-2) | MLV p ≤ 10 | 10 mm |
| Visible defects (EN 1850-2) | PASA | |
| Dimensional stability (EN 1107-02) | MLV L ≤ -0.2 | L = -0.2 % |
| Dimensional stability | MLV T ≤ -0.7 | T = -0.7 % |
| Dimensional stability at high temperature (ASTM D1204-2014) | <0.7 | 70°C L=0.028% T=0.024% |
| High-temperature dimensional stability (ASTM D1204-2014) | <0.7 | -26°C L=-0.029% T=0.018% |
| Technical data | ||
| Water resistance (EN 1928 Method B) | PASA | |
| Water resistance (ASTM D4068-2017) | COMPLETELY WATERPROOF | |
| Elongation (EN 12311-2 Method A) | MLV L ≥ 25 | L = 25 % |
| Elongation (EN 12311-2 Method A) | MLV T ≥ 200 | T = 200 % |
| Impact resistance (EN 12691) | MLV T ≥ 200 | 200 mm |
| Static load resistance (EN 12730 Method B) | MLV ≥ 20 | 20 kg |
| Flexibility at low temperatures (EN 495-5) | MLV ≥ 40 | -40 °C |
| Reaction to fire (EN 13501-1) | Euroclass E | |
| Cut resistance of overlaps (EN 12317-2) | MLV ≥ 600 | 600 N/50 mm |
| Shear strength of overlaps (ASTM D751-2006) | 16 (minimum required value) | 49.16 lbs./2” |
| Tensile strength (EN 12311-2 Method A) | MLV L ≥ 450 | L = 450 N/50 mm |
| Tensile strength (EN 12311-2 Method A) | MLV T ≥ 150 | T = 150 N/50 mm |
| Tensile strength (ASTM D751-2006) | 170 (minimum required value) | L = 3847.9 PSI |
| Tensile strength (ASTM D751-2006) | 170 (minimum required value) | T = 1215.5 PSI |
| Crack bridging capacity (UNE EN 1062-7 Method C) | 1.5 mm | |
| Alkali resistance (UNE EN 1847) | Category 1* | |
| Resistance to microorganisms (ANSI A118.10-2014) | APPROVED | |
| Resistance to contact with chemicals (EN 1847) | No change in values after 28 days in a saturated calcium hydroxide solution at 23 °C | |
| Water vapour | ||
| Water vapour transmission (ASTM E96-2016) | 8.07 g/24 h·m² | |
| Resistance to water vapour diffusion | > 2.7 m²·h·Pa/mg | 9.75 m²·h·Pa/mg |
| Vapour permeability | 67.35 ng/Pa·s·m² | |
| Permeance | 1.18 grains/h·in.Hg·ft² | |
| Other data | ||
| Water resistance of overlays with C2 cementitious adhesive (water column 1 m / 24 h) | WATERPROOF | |
| Initial adhesion of C2 cementitious adhesive to the foil: tensile strength | ≥ 0.5 MPa | |
| Adhesion of C2 cementitious adhesive to the foil after 20 days’ immersion in water: tensile strength | ≥ 0.5 MPa | |
| Adhesion of C2 cementitious adhesive to the foil: shear strength (ASTM C482-2002) | > 50 | 132.4 PSI |
| Impact resistance on ceramic tiles, steel ball test (CSTB methodology) | 4 impacts | |
Contact our team for personalized support and product guidance.