Tile 480 is a powdered cementitious adhesive, available in white and grey, made from high-strength cement, selected aggregates, a high proportion of synthetic resins and specific additives, specially formulated for the installation of large-format porcelain and glazed stoneware tiles, as well as for the installation of ceramic tiles of all types (except thin slabs) and sizes (with the longest side up to 120 cm) and all types of natural stone in large formats, provided they are not sensitive to water or prone to staining and deformation, including for applications on substrates characterised by a certain degree of movement. Once mixed with water, it produces an adhesive with excellent workability, superb thixotropy, high flexibility and strong adhesion to all types of substrates, including old ceramic floor and wall tiles. When applied vertically, it does not run and prevents tiles from slipping. The extended open time allows for safe installation even in hot and draughty conditions. The flexibility of the cured adhesive allows it to absorb movement in the substrate, meaning it can also be used for bonding floors subject to heavy loads. It is resistant to freeze-thaw cycles. Tile 480 is classified as a Class C2 TE S1 cementitious adhesive in accordance with EN 12004. The product is certified as EC 1 Plus by GEV for its extremely low emissions of volatile organic compounds.
Instructions for use
Preparation for installation
Substrates must be sufficiently dry, strong, sound and even, free from oil and grease, dust, loose material and general dirt, and free from any paint film residues; they must be adequately cured and free from significant shrinkage. As a general guide, traditional cement screeds with normal setting and hardening times must have been left to cure for at least 28 days; cement plasters or plasters based on mixed mortar must be left to dry for at least 14 days. Major surface imperfections and irregularities, such as unevenness, cavities and gravel pockets, must be levelled out if they are deeper than 20 mm using self-levelling compounds such as Livellina 5-30, Livellina HS, or, on walls, with suitable mortars such as Multimix Evo, Rinnova or Restauro. Particularly porous or crumbling substrates, and those with very low mechanical strength that are easily scratched, must first be treated with Tile Primer.
Product preparation
Mix grey Tile 480 with approx. 30% clean water (equivalent to 7.50 litres per 25 kg bag) or white Tile 480 with approx. 30 per cent water (equivalent to 7.50 litres per 25 kg bag) as follows: pour almost all the required water into a suitable container, then slowly add the powdered product, stirring the mixture as it forms using a low-speed drill fitted with a suitable mixing paddle. Once all the powder has been added, pour in the remaining water
and mix until the mixture is homogeneous and free of lumps, taking particular care to remove any lumps of unmixed material from the sides and bottom of the container. Leave to rest for about 5 minutes, then stir briefly. The adhesive prepared in this way remains workable in the mixing container for about 5 hours under normal conditions (at +20 °C); higher temperatures shorten the workability time, whilst lower temperatures extend it.
In the event of direct sunlight, and consequently high substrate temperatures, it is advisable to dampen the substrate with a sponge to cool it down, without leaving any surface water.
Installation instructions
Apply the adhesive using a suitable notched trowel, the size of the notches on which will depend on the type and size of the tiles to be laid, so as to ensure complete coverage of the back of the tiles. For better adhesion, it is advisable to first spread a thin, even layer of adhesive onto the substrate using the smooth side of the notched trowel, and then immediately apply a second layer of the desired thickness using the notched side. Apply the tiles by exerting adequate pressure and applying a slight translational movement to them. When bonding tiles with a pronounced profile on the underside, for external applications – particularly in areas subject to significant temperature fluctuations or freeze-thaw cycles – when laying on underfloor heating systems and on floors subject to heavy loads, when laying in baths and swimming pools, and when laying medium- and large-format tiles (length of the longest side >30 cm), it is essential to use the ‘compact-layer laying’ technique: the mixed adhesive is spread onto the substrate using a notched trowel and then applied to the back of the tile with a trowel, levelling it flush with the raised areas. Provided that a sufficient quantity of adhesive has been applied, this ensures that the adhesive-to-tile contact extends across the entire bonding surface (an essential requirement for the installation of floor and wall coverings exposed to freeze-thaw cycles and significant water stress).
For laying glass mosaic tiles and for installation in baths and swimming pools, mix with Flex diluted 1:1 with water. Tiles must be laid only within the time interval during which the applied adhesive is still fresh and tacky, i.e. before a surface skin has formed. This time interval is known as the adhesive’s ‘open time’ and depends on environmental conditions. The open time of Tile 480 is greater than 30 minutes at +23 °C and 50% RH. High temperatures, direct sunlight and strong draughts, as well as a highly porous and absorbent substrate, can significantly reduce the open time, whilst low temperatures, high ambient humidity and non-absorbent substrates are favourable conditions for achieving a longer open time. If the open time has elapsed and the applied adhesive has formed a skin on the surface, it is necessary to go over it again with a notched trowel to break the skin and ‘refresh’ it.
Under no circumstances should you wet the surface, as this would form a water film that prevents the tiles from adhering to the adhesive, irreparably compromising the installation. Tiles should not normally be wetted before laying; only in the case of tiles with a dusty underside is it advisable to wash them by immersing them in clean water for a few seconds. For gypsum or anhydrite substrates, pre-treatment with Tile Primer or Multigrip is absolutely essential.
Cleaning
The tools used for installation can be cleaned with water before the adhesive sets; afterwards, cleaning can only be carried out by mechanical removal. Any dirt on the surface of the tiles must also be wiped off with a damp cloth before the adhesive sets.