Guaina EPDM con butile un lato

EPDM flashing and perimeter seal for curtain walls/ventilated façades and windows and doors.

EPDM flashing and perimeter seal for curtain walls/ventilated façades and windows and doors.

  • Elastomeric membrane offering a good combination of high elasticity and tensile strength
  • Excellent resistance to UV radiation and ozone
  • Retains its elasticity and flexibility even at temperatures below -45 °C
  • Resistant to thermal shock up to +130 °C
  • Excellent resistance to acid rain

Discover more

Other solutions you might be interested in

Details

40 mm EPDM membrane with a butyl adhesive backing. When installed between façade/window elements and the masonry, it provides effective weatherproofing as well as a reliable and durable vapour barrier. Easy to install and flexible, it adapts to any building substrate and accommodates its movements.

Instructions for use

The installation surface must be compact, clean, smooth, dry and free from sharp edges, stones, small cavities, loose or foreign materials, vegetation, roots, oils, greases or other substances that could damage the membrane. Organic and compacted materials must be removed.
Allow the membrane to settle for at least 30 minutes before making the joints. For joints not subject to lateral tearing, use Sheet Metal Sealant.

Warnings

Contact with certain oils, petroleum-based products, grease and chlorine should be avoided.

Code Dimensions Packaging Packaging size Barcode
15587 * 150x0,5 mm cardboard 2x20 m
Barcode 8030334155871
15588 250x0,5 mm cardboard 20 m
Barcode 8030334155888
15589 * 300x0,5 mm cardboard 20 m
Barcode 8030334155895
*At request

PARAMETER AND TEST METHOD DECLARED VALUE  TOLERANCE UNIT
Area density (EN 1849-2) 1288 ± 5% g/m²
Tensile strength (MD/CD) (EN 12311-2) 9 -1 N/mm²
Elastic elongation (MD/CD) (EN 12311-2) ≥ 300 %
Dimensional stability (EN 1107-2) ≤ 0.5 %
Flexibility at low temperatures (EN 495-5) ≤ -45 °C
Static puncture resistance (EN ISO 12236) 0.7 -0.1 k/N
Piston distance prior to perforation (EN ISO 12236) 110 -5% Millimetre
Liquid tightness for high-pressure applications (4 bar = 40 m depth) (EN 1928:2000 (B)) Water tightness
Water permeability (liquid tightness) (EN 14150) 3.0 × 10⁻⁶ ± 10⁻⁶ m³ m²/g.
Methane permeability (gas resistance) (ASTM D1434) 2.25 × 10⁻³ m³ m²/g.
Durability – weather resistance (25 years) (EN 12224) Compliant
Durability – oxidation (EN 14575) Compliant
Angle of friction (EN ISO 12957-2) 27.5 ± 1 °
Resistance to root penetration (CEN/TS 14416) Compliant

 

Technical datasheet